ATmega8内部RC振荡器漂移测试 选择ATMEGA8-16PI,内部1M RC,程序为I/O取反操作,Agilent infiniium 54833A DSO 1GHz 4GSa/S数字示波器测量,LM2825-5供电。 27℃ Mean:141.313 Min:141.2439 Max:141.4173 Current:141.0/141.2 35℃ Mean:141.245 Min:141.0358 Max:141.4173 Current:140.9/141.0 40℃ Mean:141.18 Min:140.8892 Max:141.4173 Current:140.8/140.9 45℃ Mean:141.07 Min:140.7420 Max:141.4173 Current:140.7/140.8 50℃ Mean:141.03 Min:140.6983 Max:141.4173 Current:140.7/140.8 55℃ Mean:141.00 Min:140.6458 Max:141.4173 Current:140.6/140.7 60℃ Mean:140.97 Min:140.5294 Max:141.4173 Current:140.5/140.6 65℃ Mean:140.94 Min:140.4558 Max:141.4173 Current:140.4/140.5 70℃ Mean:140.91 Min:140.3302 Max:141.4173 Current:140.3/140.4 75℃ Mean:140.88 Min:140.2379 Max:141.4173 Current:140.2/140.3 80℃ Mean:140.84 Min:140.0747 Max:141.4173 Current:140.1/140.2 85℃ Mean:140.82 Min:139.9755 Max:141.4173 Current:140.0 90℃ Mean:140.76 Min:139.8568 Max:141.4173 Current:139.8 总结: Mean是整个测量范围的平均值,只能作为参考,不能作为评估;Min是整个测量范围的最小值,可以作为参考,也可以作为评估(频率漂移和温度成线性关系);Max是整个测量范围的最大值,由于随温度升高频率降低,所以该值几乎没有意义;Current是当前测量值可以作为参考,也可以作为评估。 从上面的数据可以看出,随着温度的升高,RC振荡器呈现出随温度升高而降低的趋势,但是变化不是很明显,从Min的测量值进行频率的漂移计算可以得出:(141.2439-139.9755)/141.2439=0.89%;从Current的测量值进行频率的漂移计算可以得出:(141.2-139.8)/141.2=0.85%,基本可以认为从27℃到85℃的温度范围内内部RC震荡器的频率变化了0.8-0.9左右,对于UART而言,这样的变化导致的误码率还是有限的。 频率是个比较难测量的值,以上的Mean和Current数据都只取了比较稳定的几位,但是大致的频率趋势还是很明显的。 感谢NSC美国国家半导体提供LM2825 DC-DC模块,感谢浙江立德提供免费网站空间,感谢浙江立德提供测试设备!
|